Immunity Standards for Commercial Electronic Products

This web site is being maintained by John R. Barnes, who was the President and Chief Engineer of dBi Corporation from 2002 to September 30, 2013, when we closed because ObamaCrap made it too expensive for us to remain in business.

John R. Barnes KS4GL, PE, NCE, NCT, ESDC Eng, ESDC Tech, PSE, Master EMC Design Engineer, SM IEEE
December 2, 2011
jrbarnes@iglou.com

Immunity tests check the behavior of products when exposed to various types of natural and manmade electrical noise.

The European Union (EU) has numerous Immunity standards for commercial electronic products.

Australia and New Zealand have Immunity standards for some types of commercial electronic products, based on International Electrotechnical Commission (IEC) standards. But products only need to comply with safety and emission standards to bear the C-Tick mark.

Most other nations and market areas do not have immunity standards for commercial electronic products, because they feel that these problems are self- correcting. If a product is sensitive to the types and levels of electrical noise found in the environments where people want to use it, it will act up-- causing field problems. Users will complain to the manufacturer, to other users, on the Internet, and maybe to the news media. If the product has significantly- worse noise immunity than other products of its type, this will become well known, hurting its sales and the manufacturer's reputation. Thus competition will force the manufacturer to improve the noise immunity of this and future products (perhaps going beyond international standards) to retain/ increase their market share and remain in business, all without government intervention.

Because they are life- critical or safety- critical, medical electronics and military electronics can have very- strict immunity requirements, which are not discussed in these web pages.

Most Immunity standards specify immunity tests, test levels, and performance criteria that are reasonably worst- case for all of the environments in which this type of product is likely to be used. The EU, Australia, and New Zealand require a product to be immunity tested to the most- specific product- family Immunity standard that applies to the product-- i.e. the scope of the standard covers some or all of its major functions. Thus multifunction products may need to be tested to several product- family Immunity standards. If a product doesn't fall under any product- family Immunity standards, then it should be tested to the appropriate generic Immunity standard.

This web page covers Immunity standards for:

Even if you think you know which EU standards (European Norms (EN's)) apply to a product, I suggest skimming through the titles of all the Harmonized Standards under the EMC Directive, Directive 2004/108/EC, as a doublecheck:

  1. Go to the EUR-Lex search page.
  2. Type "2004/108/EC" in the Search for box, and hit Enter.
  3. Click on "pdf" under recent entries titled "Commission communication in the framework of the implementation of ...". (For example, in late November 2011 the most recent listing was OJ C 288, dated 30.9.2011 (September 30, 2011).
  4. Look through the entire list, because Emission and Immunity standards for a product family aren't always close to one another.
  5. The Harmonics (EN 61000-3-2) and Flicker (EN 61000-3-3) standards apply to all alternating-current- (AC-) powered products.

To find more information about recent EN standards, such as the most recent version(s) and amendment(s) if you have an undated reference:

  1. Go to the CENELEC Advanced search page.
  2. In the Key words box, type in a standard number (such as "61000-6-4", "61000-6-4:2007", "EN 61000-6-4", or "EN 61000-6-4:2007"), or an amendment number (such as "EN 61000-6-4:2007/A1" or "EN 61000-6-4:2007/A1:2011"), and hit Enter.
  3. Click on the link for the standard/ amendment (an "Fp" means that work on this document is still in process, and it has not yet been approved).
  4. If the Reference Document line (about 1/2 way down the page) says "(MOD)", the EN standard/ amendment differs from the reference standard somehow; if it says "(EQV)", the documents are identical.
  5. Dav (date of availability, in the form yyyy-mm-dd) is the date that the EN standard/ amendment is released to the National Standards Bodies in all of the EU's official languages. These Bodies then have until the Dop (date of publication) to publish the standard/ amendment.
  6. Dow (date of withdrawal, in the form yyyy-mm-dd) is the latest date at which any conflicting (earlier) national standards must be withdrawn. This is usually the same as the Date of cessation of presumption of conformity of the superceded standard (DOCOPOCOSS) in lists of Harmonized Standards in the Official Journal of the European Union (OJ). But if they disagree, use the DOCOPOCOSS.

If you do not have an EN standard, or its reference CISPR/ IEC standard, sometimes you can find the scope as follows:

  1. Write down the reference standard/ amendment (in parentheses under the title of the EN standard). If this says "(modified)", the EN version differs from the reference standard/ amendment in some way.
  2. Go to the IEC Advanced search page.
  3. In the Publications box, choose the appropriate header (CISPR, IEC, etc.).
  4. Type the standard number in the Reference box, and hit Enter.
  5. Click on the link for the standard/ amendment you want.
  6. If you are lucky, you will see a preview box after the title of the standard-- click on it.
  7. Scroll down through the preview, looking for a section titled "scope".
  8. Read through the scope, to see if it applies to your product.

To find a corresponding Australia/ New Zealand standard:

  1. Go to SAI Global.
  2. In the Search box, type a standard number ("EN xxxxx", "CISPR xx", "IEC xxxxx", etc.) and hit Enter.
  3. Look for an AS/NZS standard with a similar number.
  4. If the description says MOD, the AS/NZS standard differs from the reference standard in some way.
  5. Click on the description to read about the AS/NZS standard.
  6. If it has Preview under the description, click on this to read the first few pages of the standard.

If you need to buy a standard, I recommend going through the steps above to find all of the equivalent versions (EN, CISPR, IEC, AS/NZS) that might meet your needs. Then check the prices of each of these at several companies that sell standards. It is quite common to find a 2:1 spread in prices between different suppliers of the identical or equivalent standards and amendments. For amendments to IEC and CISPR standards, you may have a choice of buying the base standard and its amendments separately, or buying a consolidated edition. A consolidated edition x.y will have base standard edition x merged with its amendments 1 through y. In a number of my recent purchases of I.S. EN standards (published by the National Standards Authority of Ireland) as .pdf files from SAI Global, I've been pleasantly surprised to discover that they included the first amendment at no extra cost.

I prefer to buy standards/ amendments as .pdf files, because I can usually download them within minutes of placing my order, versus waiting days to sometimes months to get hardcopies. I'll print out a hardcopy for our Standards Library, as our primary reference, and keep the .pdf file on my computer where I can search it using Adobe Acrobat or Adobe Acrobat Reader.

Immunity standards are usually organized around different types of "ports" through which noise can enter a product:

Most Immunity standards have a table for each type of port, listing:

Enclosures are usually subjected to:

AC power inputs and outputs are usually subjected to:

DC power inputs and outputs are usually subjected to:

Signal and control cables are usually subjected to:

Telecommunication cables are usually subjected to:

Protective-grounding conductors usually aren't tested.



The table below summarizes the evolution of Immunity standards for information technology equipment (ITE)-- equipment that inputs/ stores/ modifies/ outputs data. The links take you to summaries of the standards and their amendments. "(Modified)" means that the standard/ amendment differs from the reference standard/ amendment. Entries in bold text are currently active for undated references. Please note that in Australia and New Zealand, products only need to comply with safety and emission standards to bear the C-Tick mark.

Evolution of Immunity Standards for Information Technology Equipment (ITE)
Year Reference Year European Union Year Australia & New Zealand Notes
1997 CISPR 24:1997 Edition 1 1998 EN 55024:1998 (Modified) 2002 AS/NZS CISPR 24:2002  
2001 CISPR 24:1997 +A1:2001 2002 EN 55024:1998 (Modified) +A1:2001 2009 AS/NZS CISPR 24:2002 +A1:2009  
2002 CISPR 24:1997 +A1:2001+A2:2002 2003 EN 55024:1998 (Modified) +A1:2001+A2:2003 (may use until 1 DEC 2013) 2009 AS/NZS CISPR 24:2002 +A1:2009+A2:2009  
2010 CISPR 24:2010 Edition 2 2010 EN 55024:2010      



The table below summarizes the evolution of Immunity standards for radio and television broadcast receivers, and associated equipment. The links take you to summaries of the standards and their amendments. "(Modified)" means that the standard/ amendment differs from the reference standard/ amendment. Entries in bold text are currently active for undated references. Please note that in Australia and New Zealand, products only need to comply with safety and emission standards to bear the C-Tick mark.

Evolution of Immunity Standards for Radio and Television Broadcast Receivers
Year Reference Year European Union Year Australia & New Zealand Notes
1997 CISPR 20:1996 +A1:1997+A2:1997     1997 AS/NZS 4053:1997  
        2000 AS/NZS 4053:1997 +A1:2000  
2002 CISPR 20:2002 Edition 5 2002 EN 55020:2002      
2002 CISPR 20:2002 +A1:2002 2003 EN 55020:2002 +A1:2003      
2004 CISPR 20:2002 +A1:2002+A2:2004

CISPR 20:2005 Edition 5.2

2005 EN 55020:2002 +A1:2003+A2:2005 2006 AS/NZS CISPR 20:2006  
2006 CISPR 20:2006 Edition 6 2007 EN 55020:2007 2009 AS/NZS CISPR 20:2009  



The table below summarizes the evolution of Immunity standards for measurement, process control, and laboratory equipment. The links take you to summaries of the standards and their amendments. "(Modified)" means that the standard/ amendment differs from the reference standard/ amendment. Entries in bold text are currently active for undated references. Please note that in Australia and New Zealand, products only need to comply with safety and emission standards to bear the C-Tick mark.

Evolution of Immunity Standards for Measurement, Process Control, and Laboratory Equipment
Year Reference Year European Union Year Australia & New Zealand Notes
1997 IEC 61326:1997 1997 EN 61326:1997      
1998 IEC 61326:1997 +A1:1998 1998 EN 61326:1997 +A1:1998      
2000 IEC 61326:1997 +A1:1998+A2:2000 2001 EN 61326:1997 +A1:1998+A2:2001      
2002 IEC 61326:2002 Edition 1 2003 EN 61326:1997 +A1:1998+A2:2001 +A3:2003      
2005 IEC 61326-1:2005 Edition 1 &

IEC 61326-2-3:2006 Edition 1 &

others

2006 EN 61326-1:2006 &

EN 61326-2-3:2006 &

others

     



The table below summarizes the evolution of Immunity standards for lamps and luminaires. The links take you to summaries of the standards and their amendments. "(Modified)" means that the standard/ amendment differs from the reference standard/ amendment. Entries in bold text are currently active for undated references. Please note that in Australia and New Zealand, products only need to comply with safety and emission standards to bear the C-Tick mark.

Evolution of Immunity Standards for Lamps and Luminaires
Year Reference Year European Union Year Australia & New Zealand Notes
1995 IEC 61547:1995 Edition 1 1995 EN 61547:1995      
2000 IEC 61547:1995 +A1:2000 2000 EN 61547:1995 +A1:2000 (may use until 1 JUL 2012)      
2009 IEC 61547:2009 Edition 2 2009 EN 61547:2009      



The table below summarizes the evolution of Immunity standards for household appliances and electric tools. The links take you to summaries of the standards and their amendments. "(Modified)" means that the standard/ amendment differs from the reference standard/ amendment. Entries in bold text are currently active for undated references. Please note that in Australia and New Zealand, products only need to comply with safety and emission standards to bear the C-Tick mark.

Evolution of Immunity Standards for Household Appliances and Electric Tools
Year Reference Year European Union Year Australia & New Zealand Notes
1997 CISPR 14-2:1997 Edition 1 1997 EN 55014-2:1997      
2001 CISPR 14-2:1997 +A1:2001

CISPR 14-2:2001 Edition 1.1

2001 EN 55014-2:1997 +A1:2001 2003; AS/NZS CISPR 14.2:2003  
2008 CISPR 14-2:1997 +A1:2001+A2:2008 2008 EN 55014-2:1997 +A1:2001+A2:2008      



The table below summarizes the evolution of Immunity standards for generic products to be used in residential, commercial, and light- industrial environments. The links take you to summaries of the standards and their amendments. "(Modified)" means that the standard/ amendment differs from the reference standard/ amendment. Entries in bold text are currently active for undated references. Please note that in Australia and New Zealand, products only need to comply with safety and emission standards to bear the C-Tick mark.

Evolution of Immunity Standards for Generic Products to be Used in Residential, Commercial, and Light- Industrial Environments
Year Reference Year European Union Year Australia & New Zealand Notes
    1992 EN 50082-1:1992      
    1997 EN 50082-1:1997      
1997 IEC 61000-6-1:1997 Edition 1 2001 EN 61000-6-1:2001 (Modified)      
2005 IEC 61000-6-1:2005 Edition 2 2007 EN 61000-6-1:2007 2006 AS/NZS 61000.6.1:2006  



The table below summarizes the evolution of Immunity standards for generic products to be used in industrial environments. The links take you to summaries of the standards and their amendments. "(Modified)" means that the standard/ amendment differs from the reference standard/ amendment. Entries in bold text are currently active for undated references. Please note that in Australia and New Zealand, products only need to comply with safety and emission standards to bear the C-Tick mark.

Evolution of Immunity Standards for Generic Products to be Used in Industrial Environments
Year Reference Year European Union Year Australia & New Zealand Notes
    1995 EN 50082-2:1995      
1999 IEC 61000-6-2:1999 Edition 1 1999 EN 61000-6-2:1999      
    2001 EN 61000-6-2:2001 (Modified)      
2005 IEC 61000-6-2:2005 Edition 2 2005 EN 61000-6-2:2005 2006 AS/NZS 61000.6.2:2006  



AS/NZS 4053:1997 Limits and methods of measurement of immunity characteristics of sound and television broadcast receivers and associated equipment

Equivalent to: CISPR 20:1996+A1:1997+A2:1997
Replaces:
Replaced by: AS/NZS 4053:1997+A1:2000

For: Australia & New Zealand
Ratified/printed: 5 FEB 1997
May use starting:
Must use starting:
Must use until:
May use until:

References:
* AS/NZS 1052
* AS/NZS 1052.1
* AS/NZS 1053
* AS/NZS 1127.8
* AS/NZS 1852
* AS/NZS 3871.2
* IEC 96-1:1986
* IEC 60728-2

Referenced by:

Comments:

(hardcopy & E:\dbi\4053.pdf)



AS/NZS 4053:1997+A1:2000 Limits and methods of measurement of immunity characteristics of sound and television broadcast receivers and associated equipment

Equivalent to:
Replaces: AS/NZS 4053:1997
Replaced by: AS/NZS CISPR 20:2006

For: Australia & New Zealand
Ratified/printed: 25 MAY 2000
May use starting:
Must use starting:
Must use until:
May use until:

References:
* AS/NZS 1052
* AS/NZS 1052.1
* AS/NZS 1053
* AS/NZS 1127.8
* AS/NZS 1852
* AS/NZS 3871.2
* IEC 96-1:1986
* IEC 60728-2

Referenced by:

Comments:

(hardcopy & E:\dbi\4053_AMD1.pdf)



AS/NZS 61000.6.1:2006 Electromagnetic Compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments

Equivalent to: IEC 61000-6-1:2005 Edition 2
Replaces:
Replaced by:

For: Australia & New Zealand
Ratified/printed: 1 JUN 2006
May use starting: 1 JUN 2006
Must use starting: 1 JUN 2008
Must use until:
May use until:

References:
* AS/NZS CISPR 22
* AS/NZS 61000.4.2
* AS/NZS 61000.4.3
* AS/NZS 61000.4.4
* AS/NZS 61000.4.5
* AS/NZS 61000.4.6
* AS/NZS 61000.4.8
* AS/NZS 61000.4.11
* IEC 60050-161

Referenced by:

Comments:

(hardcopy & E:\dbi\iec61000-6-1{ed2.0}b.pdf)



AS/NZS 61000.6.2:2006 Electromagnetic Compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments

Equivalent to: IEC 61000-6-2:2005 Edition 2
Replaces:
Replaced by:

For: Australia & New Zealand
Ratified/printed: 1 JUN 2006
May use starting: 1 JUN 2006
Must use starting: 1 JUN 2008
Must use until:
May use until:

References:
* AS/NZS CISPR 22
* IEC 60050-161
* AS/NZS 61000.4.2
* AS/NZS 61000.4.3
* AS/NZS 61000.4.4
* AS/NZS 61000.4.5
* AS/NZS 61000.4.6
* AS/NZS 61000.4.8
* AS/NZS 61000.4.11

Referenced by:

Comments:

(hardcopy & E:\dbi\61000-6-2_2005.pdf)



AS/NZS CISPR 14.2:2003 Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard

Equivalent to: CISPR 14-2:1997+A1:2001 & CISPR 14-2:2001 Edition 1.1
Replaces:
Replaced by:

For: Australia & New Zealand
Ratified/printed: 9 OCT 2003
May use starting: 9 OCT 2003
Must use starting: 9 OCT 2005
Must use until:
May use until:

References:
* CISPR 11:1990
* CISPR 14-1:2000
* CISPR 16-1:1993
* CISPR 16-2:1996
* IEC 60050(161):1990
* IEC 61000-4-2:1995
* IEC 61000-4-3:1995
* IEC 61000-4-4:1995
* IEC 61000-4-5:1995
* IEC 61000-4-6:1996
* IEC 61000-4-11:1994

Referenced by:

Comments:

(hardcopy & E:\dbi\CISPR14-2.pdf)



AS/NZS CISPR 20:2006 Sound and television broadcast receivers and associated equipment - Immunity characteristics - Limits and methods of measurement

Equivalent to: CISPR 20:2002+A1:2002+A2:2004 & CISPR 20:2005 Edition 5.2
Replaces: AS/NZS 4053:1997+A1:2000
Replaced by: AS/NZS CISPR 20:2009

For: Australia & New Zealand
Ratified/printed: 2 JUN 2006
May use starting: 2 JUN 2006
Must use starting: 2 JUN 2008
Must use until: 21 AUG 2009
May use until: 21 AUG 2011

References:
* CISPR 16-1
* CISPR 16-3
* AS/NZS CISPR 22
* AS/NZS CISPR 24
* ETS 300 158:1992
* ETS 300 249:1993
* IEC 60050(161)
* IEC 60268-1
* IEC 60651
* IEC 60728-2
* AS/NZS 61000.4.2
* AS/NZS 61000.4.3
* AS/NZS 61000.4.4

Referenced by:
* AS/NZS CISPR 24:2002+A1:2009+A2:2009 (undated)

Comments:

(hardcopy & E:\dbi\AS_NZSCISPR20-2006.pdf)



AS/NZS CISPR 20:2009 Sound and television broadcast receivers and associated equipment - Immunity characteristics - Limits and methods of measurement

Equivalent to: CISPR 20:2006 Edition 6
Replaces: AS/NZS CISPR 20:2006
Replaced by:

For: Australia & New Zealand
Ratified/printed: 21 AUG 2009
May use starting: 21 AUG 2009
Must use starting: 21 AUG 2011
Must use until:
May use until:

References:
* CISPR 16-1-3
* ETS 300 158:1992
* ETS 300 249:1993
* IEC 60050(161)
* IEC 60268-1:1985
* IEC 61000-4-2
* IEC 61000-4-3
* IEC 61000-4-4
* IEC 61672-1:2002

Referenced by:
* AS/NZS CISPR 24:2002+A1:2009+A2:2009 (undated)

Comments:

(hardcopy & E:\dbi\ISEN55020-2007.pdf)



AS/NZS CISPR 24:2002 Information technology equipment - Immunity characteristics - Limits and methods of measurement

Equivalent to: CISPR 24:1997 Edition 1
Replaces:
Replaced by: AS/NZS CISPR 24:2002+A1:2009

For: Australia & New Zealand
Ratified/printed: 21 JAN 2002
May use starting: 21 JAN 2002
Must use starting: 21 JAN 2004
Must use until: 2 SEP 2009
May use until: 2 SEP 2011

References:
* CISPR 22:1997
* IEC 60050(161):1990
* IEC 60318:1970
* IEC 61000-4-2:1995
* IEC 61000-4-3:1995
* IEC 61000-4-4:1995
* IEC 61000-4-5:1995
* IEC 61000-4-6:1996
* IEC 61000-4-8:1993
* IEC 61000-4-11:1994
* ISO 9241-3:1992

Referenced by:
* AS/NZS CISPR 20:2006 (undated)

Comments:

(hardcopy)



AS/NZS CISPR 24:2002+A1:2009 Information technology equipment - Immunity characteristics - Limits and methods of measurement

Equivalent to: CISPR 24:1997+A1:2001
Replaces: AS/NZS CISPR 24:2002
Replaced by: AS/NZS CISPR 24:2002+A1:2009+A2:2009

For: Australia & New Zealand
Ratified/printed: 2 SEP 2009
May use starting: 2 SEP 2009
Must use starting: 2 SEP 2011
Must use until: 2 SEP 2009
May use until: 2 SEP 2011

References:
* CISPR 22:1997
* IEC 60050(161):1990
* IEC 60318:1970
* IEC 61000-4-2:1995
* IEC 61000-4-3:1995
* IEC 61000-4-4:1995
* IEC 61000-4-5:1995
* IEC 61000-4-6:1996
* IEC 61000-4-8:1993
* IEC 61000-4-11:1994
* ISO 9241-3:1992

Referenced by:
* AS/NZS CISPR 20:2006 (undated)

Comments:

(hardcopy & E:\dbi\AS NZS CISPR 24-2002 Amdt 1-2009.pdf)



AS/NZS CISPR 24:2002+A1:2009+A2:2009 Information technology equipment - Immunity characteristics - Limits and methods of measurement

Equivalent to: CISPR 24:1997+A1:2001+A2:2002
Replaces: AS/NZS CISPR 24:2002+A1:2009
Replaced by:

For: Australia & New Zealand
Ratified/printed: 2 SEP 2009
May use starting: 2 SEP 2009
Must use starting: 2 SEP 2011
Must use until:
May use until:

References:
* AS/NZS CISPR 20
* CISPR 22:1997
* IEC 60050(161):1990
* IEC 60318:1970
* IEC 61000-4-2:1995
* IEC 61000-4-3:1995
* IEC 61000-4-4:1995
* IEC 61000-4-5:1995
* IEC 61000-4-6:1996
* IEC 61000-4-8:1993
* IEC 61000-4-11:1994
* ISO 9241-3:1992

Referenced by:
* AS/NZS CISPR 20:2006 (undated)

Comments:

(hardcopy & E:\dbi\AS NZS CISPR 24-2002 Amdt 2-2009.pdf)



CISPR 14-2:1997 Edition 1 Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard

Equivalent to: EN 55014-2:1997
Replaces:
Replaced by: CISPR 14-2:1997+A1:2001 & CISPR 14-2:2001 Edition 1.1

For:
Ratified/printed: 7 FEB 1997
May use starting: 7 FEB 1997
Must use starting: 7 FEB 1997
Must use until: 20 AUG 2001
May use until: 20 AUG 2001

References:
* CISPR 11:1990
* CISPR 14:1993
* CISPR 16-1:1993
* IEC 50(161):1990
* IEC 1000-4-2:1995
* IEC 1000-4-3:1995
* IEC 1000-4-4:1995
* IEC 1000-4-5:1995
* IEC 1000-4-6:1996
* IEC 1000-4-11:1994

Referenced by:

Comments:

(hardcopy & E:\dbi\SS EN 55014-2.pdf & E:\dbi\SS-EN+55014-2.pdf)



CISPR 14-2:1997+A1:2001, or consolidated edition CISPR 14-2:2001 Edition 1.1 Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard

Equivalent to: EN 55014-2:1997+A1:2001 & AS/NZS CISPR 14.2:2003
Replaces: CISPR 14-2:1997 Edition 1
Replaced by: CISPR 14-2:1997+A1:2001+A2:2008

For:
Ratified/printed: 20 AUG 2001
May use starting: 20 AUG 2001
Must use starting: 20 AUG 2001
Must use until: 27 MAY 2008
May use until: 27 MAY 2008

References:
* CISPR 11:1990
* CISPR 14-1:2000
* CISPR 16-1:1993
* CISPR 16-2:1996
* IEC 60050(161):1990
* IEC 61000-4-2:1995
* IEC 61000-4-3:1995
* IEC 61000-4-4:1995
* IEC 61000-4-5:1995
* IEC 61000-4-6:1996
* IEC 61000-4-11:1994

Referenced by:

Comments:

(hardcopy & E:\dbi\CISPR14-2.pdf & E:\dbi\cispr14-2-amd1{ed1[1].0}b.pdf)



CISPR 14-2:1997+A1:2001+A2:2008 Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard

Equivalent to: EN 55014-2:1997+A1:2001+A2:2008
Replaces: CISPR 14-2:1997+A1:2001 & CISPR 14-2:2001 Edition 1.1
Replaced by:

For:
Ratified/printed: 27 MAY 2008
May use starting: 27 MAY 2008
Must use starting: 27 MAY 2008
Must use until:
May use until:

References:
* CISPR 14-1:2005
* IEC 61000-4-2:1995+A1:1998+A2:2000
* IEC 61000-4-3:2006+A1:2007
* IEC 61000-4-4:2004
* IEC 61000-4-5:2005
* IEC 61000-4-6:2003+A1:2004+A2:2006
* IEC 61000-4-11:2004
* IEC 60050-161

Referenced by:

Comments:

(hardcopy & E:\dbi\cispr14-2-amd2{ed1.0}b.pdf)



CISPR 20:2002 Edition 5 Sound and television broadcast receivers and associated equipment - Immunity characteristics - Limits and methods of measurement

Equivalent to: EN 55020:2002
Replaces: previous edition of CISPR 20 and its amendments
Replaced by: CISPR 20:2002+A1:2002

For:
Ratified/printed: 2002
May use starting: 2002
Must use starting: 2002
Must use until: 2003
May use until: 2003

References:
* CISPR 16-1
* CISPR 16-3
* CISPR 22
* CISPR 24
* ETS 300 158:1992
* ETS 300 249:1993
* IEC 60050(161)
* IEC 60268-1
* IEC 60651
* IEC 60728-2
* IEC 61000-4-2
* IEC 61000-4-3
* IEC 61000-4-4

Referenced by:

Comments:

(source)



CISPR 20:2002+A1:2002 Sound and television broadcast receivers and associated equipment - Immunity characteristics - Limits and methods of measurement

Equivalent to: EN 55020:2002+A1:2003
Replaces: CISPR 20:2002 Edition 5
Replaced by: CISPR 20:2002+A1:2002+A2:2004 & CISPR 20:2005 Edition 5.2

For:
Ratified/printed: 2003
May use starting: 2003
Must use starting: 2003
Must use until: 2004
May use until: 2004

References:
* CISPR 16-1
* CISPR 16-3
* CISPR 22
* CISPR 24
* ETS 300 158:1992
* ETS 300 249:1993
* IEC 60050(161)
* IEC 60268-1
* IEC 60651
* IEC 60728-2
* IEC 61000-4-2
* IEC 61000-4-3
* IEC 61000-4-4

Referenced by:

Comments:

(source)



CISPR 20:2002+A1:2002+A2:2004, or consolidated edition CISPR 20:2005 Edition 5.2 Sound and television broadcast receivers and associated equipment - Immunity characteristics - Limits and methods of measurement

Equivalent to: EN 55020:2002+A1:2003+A2:2005 & AS/NZS CISPR 20:2006
Replaces: CISPR 20:2002+A1:2002
Replaced by: CISPR 20:2006 Edition 6

For:
Ratified/printed: 2004
May use starting: 2004
Must use starting: 2004
Must use until: 27 NOV 2006
May use until: 27 NOV 2006

References:
* CISPR 16-1
* CISPR 16-3
* CISPR 22
* CISPR 24
* ETS 300 158:1992
* ETS 300 249:1993
* IEC 60050(161)
* IEC 60268-1
* IEC 60651
* IEC 60728-2
* IEC 61000-4-2
* IEC 61000-4-3
* IEC 61000-4-4

Referenced by:

Comments:

(hardcopy & E:\dbi\cispr20{ed5[1].2}b.pdf)



CISPR 20:2006 Edition 6 Sound and television broadcast receivers and associated equipment - Immunity characteristics - Limits and methods of measurement

Equivalent to: EN 55020:2007 & AS/NZS CISPR 20:2009
Replaces: CISPR 20:2002+A1:2002+A2:2004 & CISPR 20:2005 Edition 5.2
Replaced by:

For:
Ratified/printed: 27 NOV 2006
May use starting: 27 NOV 2006
Must use starting: 27 NOV 2006
Must use until:
May use until:

References:
* CISPR 16-1-3
* ETS 300 158:1992
* ETS 300 249:1993
* IEC 60050(161)
* IEC 60268-1:1985
* IEC 61000-4-2
* IEC 61000-4-3
* IEC 61000-4-4
* IEC 61672-1:2002

Referenced by:
* CISPR 24:2010 2nd Edition
* EN 55024:1998+A1:2001+A2:2003

Comments:

(hardcopy & E:\dbi\ISEN55020-2007.pdf)



CISPR 24:1997 Edition 1 Information technology equipment - Immunity characteristics - Limits and methods of measurement

Equivalent to: EN 55024:1998 (unmodified)
Replaces:
Replaced by: CISPR 24:1997+A1:2001

For:
Ratified/printed: 5 SEP 1997
May use starting: 5 SEP 1997
Must use starting: 5 SEP 1997
Must use until: 18 JUL 2001
May use until: 18 JUL 2001

References:
* CISPR 22:1997
* IEC 60050(161):1990
* IEC 60318:1970
* IEC 61000-4-2:1995
* IEC 61000-4-3:1995
* IEC 61000-4-4:1995
* IEC 61000-4-5:1995
* IEC 61000-4-6:1996
* IEC 61000-4-8:1993
* IEC 61000-4-11:1994
* ISO 9241-3:1992

Referenced by:
* CISPR 20:2002 (undated)
* EN 55020:2002 (undated)

Comments:

(source)



CISPR 24:1997+A1:2001 Information technology equipment - Immunity characteristics - Limits and methods of measurement

Equivalent to: EN 55024:1998+A1:2001 (unmodified)
Replaces: CISPR 24:1997 Edition 1
Replaced by: CISPR 24:1997+A1:2001+A2:2002

For:
Ratified/printed: 18 JUL 2001
May use starting: 18 JUL 2001
Must use starting: 18 JUL 2001
Must use until: 29 OCT 2002
May use until: 29 OCT 2002

References:
* CISPR 22:1997
* IEC 60050(161):1990
* IEC 60318:1970
* IEC 61000-4-2:1995
* IEC 61000-4-3:1995
* IEC 61000-4-4:1995
* IEC 61000-4-5:1995
* IEC 61000-4-6:1996
* IEC 61000-4-8:1993
* IEC 61000-4-11:1994
* ISO 9241-3:1992

Referenced by:
* CISPR 20:2002 (undated)
* EN 55020:2002 (undated)

Comments: Annex A changed- new noise levels on telecommunication ports.

(hardcopy & E:\dbi\CISPR24A1.pdf)



CISPR 24:1997+A1:2001+A2:2002 Information technology equipment - Immunity characteristics - Limits and methods of measurement

Equivalent to: EN 55024:1998+A1:2001+A2:2003 (unmodified)
Replaces: CISPR 24:1997+A1:2001
Replaced by: CISPR 24:2010 2nd Edition

For:
Ratified/printed: 29 OCT 2002
May use starting: 29 OCT 2002
Must use starting: 29 OCT 2002
Must use until: 24 AUG 2010
May use until: 24 AUG 2010

References:
* CISPR 22:1997
* IEC 60050(161):1990
* IEC 60318:1970
* IEC 61000-4-2:1995
* IEC 61000-4-3:1995
* IEC 61000-4-4:1995
* IEC 61000-4-5:1995
* IEC 61000-4-6:1996
* IEC 61000-4-8:1993
* IEC 61000-4-11:1994
* ISO 9241-3:1992

Referenced by:
* CISPR 20:2002 Edition 5 (undated)
* EN 55020:2002 (undated)

Comments: Adds testing of multifunction equipment to Annex A

(hardcopy & E:\dbi\cispr24-amd2{ed1.0}b.pdf)



CISPR 24:2010 2nd Edition Information technology equipment - Immunity characteristics - Limits and methods of measurement

Equivalent to: EN 55024:2010
Replaces: CISPR 24:1997+A1:2001+A2:2002
Replaced by:

For:
Ratified/printed: 24 AUG 2010
May use starting: 24 AUG 2010
Must use starting: 24 AUG 2010
Must use until:
May use until:

References:
* CISPR 16-1-2:2003+A1:2004+A2:2006
* CISPR 20:2006
* CISPR 22:2008
* IEC 60050-161:1990
* IEC 60318-1:2009
* IEC 61000-4-2:2008
* IEC 61000-4-3:2006
* IEC 61000-4-4:2004
* IEC 61000-4-5:2005
* IEC 61000-4-6:2008
* IEC 61000-4-8:2009
* IEC 61000-4-11:2004

Referenced by:
* CISPR 20:2002 Edition 5 (undated)
* EN 55020:2002 (undated)

Comments: Adds testing of multifunction equipment to Annex A

(hardcopy & E:\dBi\cispr24{ed2.0}b.pdf)



EN 50082-1:1992 Electromagnetic compatibility - Generic immunity standard - Part 1: Residential, commercial and light industry

Equivalent to:
Replaces:
Replaced by: EN 50082-1:1997

For: European Union
Ratified/printed: 10 DEC 1991
May use starting: 10 APR 1992
Must use starting:
Must use until: 3 APR 1998
May use until: 1 JUL 2001

References:
* EN 55022
* IEC 50(161)
* IEC 801
* IEC 801-2:1984
* IEC 801-2:1991
* IEC 801-3:1984
* IEC 801-4:1988

Referenced by:

Comments:

(hardcopy)



EN 50082-1:1997 Electromagnetic compatibility - Generic immunity standard - Part 1: Residential, commercial and light industry

Equivalent to:
Replaces: EN 50082-1:1992
Replaced by: EN 61000-6-1:2001

For: European Union
Ratified/printed: 11 MAR 1997
May use starting: 3 APR 1998
Must use starting: 1 JUL 2001
Must use until: 9 MAR 2002
May use until: 1 JUL 2004

References:
* EN 55022
* EN 61000-4-2
* EN 61000-4-3
* EN 61000-4-4
* EN 61000-4-5
* EN 61000-4-6
* EN 61000-4-8
* EN 61000-4-11
* ENV 50204:1995
* IEC 50(161)

Referenced by:

Comments:

(hardcopy)



EN 50082-2:1995 Electromagnetic compatibility - Generic immunity standard - Part 2: Industrial environment

Equivalent to:
Replaces:
Replaced by: EN 61000-6-2:1999

For: European Union
Ratified/printed: MAR 1995
May use starting: 16 SEP 1995
Must use starting:
Must use until: 25 JAN 2000
May use until: 1 APR 2002

References:
* EN 55011
* EN 55022
* EN 61000-4-2
* EN 61000-4-4
* EN 61000-4-5
* EN 61000-4-8
* EN 61000-4-11
* ENV 50140
* ENV 50141
* ENV 50204

Referenced by:

Comments:

(hardcopy)



EN 55014-2:1997 Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard

Equivalent to: CISPR 14-2:1997 Edition 1
Replaces:
Replaced by: EN 55014-2:1997+A1:2001

For: European Union
Ratified/printed: 1 OCT 1996
May use starting: 3 APR 1998
Must use starting: 1 JAN 2001
Must use until: 10 AUG 2002
May use until: 1 DEC 2004

References:
* CISPR 16-1:1993
* EN 55011:1991
* EN 55014:1993
* EN 61000-4-2:1995
* EN 61000-4-3:1996
* EN 61000-4-4:1995
* EN 61000-4-5:1995
* EN 61000-4-6:1996
* EN 61000-4-11:1994
* IEC 50(161):1990

Referenced by:

Comments:

(hardcopy & E:\dbi\SS EN 55014-2.pdf & E:\dbi\SS-EN+55014-2.pdf)



EN 55014-2:1997+A1:2001 Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard

Equivalent to: CISPR 14-2:1997+A1:2001 & CISPR 14-2:2001 Edition 1.1
Replaces: EN 55014-2:1997
Replaced by: EN 55014-2:1997+A1:2001+A2:2008

For: European Union
Ratified/printed: 1 DEC 2001
May use starting: 10 AUG 2002
Must use starting: 1 DEC 2004
Must use until: 19 MAR 2010
May use until: 1 SEP 2011

References:
* CISPR 14-1:2000
* CISPR 16-1:1993
* CISPR 16-2:1996
* EN 55011:1991
* EN 61000-4-2:1995
* EN 61000-4-3:1996
* EN 61000-4-4:1995
* EN 61000-4-5:1995
* EN 61000-4-6:1996
* EN 61000-4-11:1994
* IEC 50(161):1990

Referenced by:

Comments:

(hardcopy & E:\dbi\cispr14-2-amd1{ed1[1].0}b.pdf)



EN 55014-2:1997+A1:2001+A2:2008 Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard

Equivalent to: CISPR 14-2:1997+A1:2001+A2:2008
Replaces: EN 55014-2:1997+A1:2001
Replaced by:

For: European Union
Ratified/printed: 1 SEP 2008
May use starting: 19 MAR 2010
Must use starting: 1 SEP 2011
Must use until:
May use until:

References:
* CISPR 14-1:2005
* IEC 61000-4-2:1995+A1:1998+A2:2000
* IEC 61000-4-3:2006+A1:2007
* IEC 61000-4-4:2004
* IEC 61000-4-5:2005
* IEC 61000-4-6:2003+A1:2004+A2:2006
* IEC 61000-4-11:2004
* IEC 60050-161

Referenced by:

Comments:

(hardcopy & E:\dbi\cispr14-2-amd2{ed1.0}b.pdf)



EN 55020:2002 Sound and television broadcast receivers and associated equipment - Immunity characteristics - Limits and methods of measurement

Equivalent to: CISPR 20:2002 Edition 5
Replaces: EN 55020:1994+A11:1996+A13:1999+A14:1999+A12:1999
Replaced by: EN 55020:2002+A1:2003

For: European Union
Ratified/printed: 1 APR 2002
May use starting: 10 AUG 2002
Must use starting: 1 APR 2005
Must use until: 22 JUL 2003
May use until: 1 DEC 2005

References:
* CISPR 16-1
* CISPR 16-3
* CISPR 22
* CISPR 24
* ETS 300 158:1992
* ETS 300 249:1993
* IEC 60050(161)
* IEC 60268-1
* IEC 60651
* IEC 60728-2
* IEC 61000-4-2
* IEC 61000-4-3
* IEC 61000-4-4

Referenced by:
* EN 55011:1991 (undated)

Comments:

(source)



EN 55020:2002+A1:2003 Sound and television broadcast receivers and associated equipment - Immunity characteristics - Limits and methods of measurement

Equivalent to: CISPR 20:2002+A1:2002
Replaces: EN 55020:2002
Replaced by: EN 55020:2002+A1:2003+A2:2005

For: European Union
Ratified/printed:
May use starting: 22 JUL 2003
Must use starting: 1 DEC 2005
Must use until: 5 OCT 2005
May use until: 1 FEB 2008

References:
* CISPR 16-1
* CISPR 16-3
* CISPR 22
* CISPR 24
* ETS 300 158:1992
* ETS 300 249:1993
* IEC 60050(161)
* IEC 60268-1
* IEC 60651
* IEC 60728-2
* IEC 61000-4-2
* IEC 61000-4-3
* IEC 61000-4-4

Referenced by:
* EN 55011:1991 (undated)

Comments:

(source)



EN 55020:2002+A1:2003+A2:2005 Sound and television broadcast receivers and associated equipment - Immunity characteristics - Limits and methods of measurement

Equivalent to: CISPR 20:2002+A1:2002+A2:2004 & CISPR 20:2005 Edition 5.2
Replaces: EN 55020:2002+A1:2003
Replaced by: EN 55020:2007

For: European Union
Ratified/printed: 1 FEB 2005
May use starting: 5 OCT 2005
Must use starting: 1 FEB 2008
Must use until: 25 SEP 2007
May use until: 1 DEC 2009

References:
* CISPR 16-1
* CISPR 16-3
* CISPR 22
* CISPR 24
* ETS 300 158:1992
* ETS 300 249:1993
* IEC 60050(161)
* IEC 60268-1
* IEC 60651
* IEC 60728-2
* IEC 61000-4-2
* IEC 61000-4-3
* IEC 61000-4-4

Referenced by:
* EN 55011:1991 (undated)

Comments:

(hardcopy & E:\dbi\cispr20{ed5[1].2}b.pdf)



EN 55020:2007 Sound and television broadcast receivers and associated equipment - Immunity characteristics - Limits and methods of measurement

Equivalent to: CISPR 20:2006 Edition 6
Replaces: EN 55020:2002+A1:2003+A2:2005
Replaced by:

For: European Union
Ratified/printed: 1 DEC 2006
May use starting: 25 SEP 2007
Must use starting: 1 DEC 2009
Must use until:
May use until:

References:
* EN 55016-1-3:2006
* EN 61000-4-2:1998
* EN 61000-4-3:2006
* EN 61000-4-4:2004
* EN 61672-1:2003

* ETS 300 158:1992
* ETS 300 249:1993
* HD 483.1 S2:1989
* IEC 60050(161)

Referenced by:
* EN 55011:1991 (undated)

Comments:

(hardcopy & E:\dbi\ISEN55020-2007.pdf)



EN 55024:1998 Information technology equipment - Immunity characteristics - Limits and methods of measurement

Equivalent to: CISPR 24:1997 Edition 1 (modified)
Replaces:
Replaced by: EN 55024:1998+A1:2001

For: European Union
Ratified/printed: 1 AUG 1998
May use starting: 27 FEB 1999
Must use starting: 1 JUL 2001
Must use until: 9 MAR 2002
May use until: 1 OCT 2004

References:
* EN 55022:1998
* EN 61000-4-2:1995
* EN 61000-4-3:1996
* EN 61000-4-4:1995
* EN 61000-4-5:1995
* EN 61000-4-6:1996
* EN 61000-4-8:1993
* EN 61000-4-11:1994
* IEC 60050(161):1990
* IEC 60318:1970
* ISO 9241-3:1992

Referenced by:

Comments:

(hardcopy & E:\dbi\ss-en55024.pdf)



EN 55024:1998+A1:2001 Information technology equipment - Immunity characteristics - Limits and methods of measurement

Equivalent to: CISPR 24:1997+A1:2001 (modified)
Replaces: EN 55024:1998
Replaced by: EN 55024:1998+A1:2001+A2:2003

For: European Union
Ratified/printed: 1 OCT 2001
May use starting: 9 MAR 2002
Must use starting: 1 OCT 2004
Must use until: 22 JUL 2003
May use until: 1 DEC 2005

References:
* EN 55022:1998
* EN 61000-4-2:1995
* EN 61000-4-3:1996
* EN 61000-4-4:1995
* EN 61000-4-5:1995
* EN 61000-4-6:1996
* EN 61000-4-8:1993
* EN 61000-4-11:1994
* IEC 60050(161):1990
* IEC 60318:1970
* ISO 9241-3:1992

Referenced by:

Comments: Annex A changed- new noise levels on telecommunication ports.

(hardcopy & E:\dbi\CISPR24A1.pdf)



EN 55024:1998+A1:2001+A2:2003 Information technology equipment - Immunity characteristics - Limits and methods of measurement

Equivalent to: CISPR 24:1997+A1:2001+A2:2002 (modified)
Replaces: EN 55024:1998+A1:2001
Replaced by: EN 55024:2010

For: European Union
Ratified/printed: 1 DEC 2002
May use starting: 22 JUL 2003
Must use starting: 1 DEC 2005
Must use until: 30 SEP 2011
May use until: 1 DEC 2013

References:
* CISPR 16-1-2:2003+A1:2004+A2:2006
* CISPR 20:2006
* CISPR 22:2008
* IEC 60050-161:1990
* IEC 60318-1:2009
* IEC 61000-4-2:2008
* IEC 61000-4-3:2006
* IEC 61000-4-4:2004
* IEC 61000-4-5:2005
* IEC 61000-4-6:2008
* IEC 61000-4-8:2009
* IEC 61000-4-11:2004

Referenced by:

Comments: Adds testing of multifunction equipment to Annex A

(hardcopy)



EN 55024:2010 Information technology equipment - Immunity characteristics - Limits and methods of measurement

Equivalent to: CISPR 24:2010
Replaces: EN 55024:1998+A1:2001+A2:2003
Replaced by:

For: European Union
Ratified/printed: 16 NOV 2010
May use starting: 30 SEP 2011
Must use starting: 1 DEC 2013
Must use until:
May use until:

References:
* EN 55022:1998
* EN 61000-4-2:1995
* EN 61000-4-3:1996
* EN 61000-4-4:1995
* EN 61000-4-5:1995
* EN 61000-4-6:1996
* EN 61000-4-8:1993
* EN 61000-4-11:1994
* IEC 60050(161):1990
* IEC 60318:1970
* ISO 9241-3:1992

Referenced by:

Comments: Adds testing of multifunction equipment to Annex A

(hardcopy & E:\dbi\cispr24-amd2{ed1.0}b.pdf)



EN 61000-6-1:2001 Electromagnetic Compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments

Equivalent to: IEC 61000-6-1:1997 Edition 1 (modified)
Replaces: EN 50082-1:1997
Replaced by: EN 61000-6-1:2007

For: European Union
Ratified/printed: 3 JUL 2001
May use starting: 9 MAR 2002
Must use starting: 1 JUL 2004
Must use until: 25 SEP 2007
May use until: 1 DEC 2009

References:
* EN 55022
* EN 61000-4-2
* EN 61000-4-3
* EN 61000-4-4
* EN 61000-4-5
* EN 61000-4-6
* EN 61000-4-8
* EN 61000-4-11
* EN 61000-6-2
* IEC 60050-161

Referenced by:

Comments:

(hardcopy)



EN 61000-6-1:2007 Electromagnetic Compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments

Equivalent to: IEC 61000-6-1:2005 Edition 2
Replaces: EN 61000-6-1:2001
Replaced by:

For: European Union
Ratified/printed: 1 DEC 2006
May use starting: 25 SEP 2007
Must use starting: 1 DEC 2009
Must use until:
May use until:

References:
* CISPR 22
* IEC 60050-161
* IEC 61000-4-2
* IEC 61000-4-3
* IEC 61000-4-4
* IEC 61000-4-5
* IEC 61000-4-6
* IEC 61000-4-8
* IEC 61000-4-11

Referenced by:
* EN 61547:2009

Comments:

(hardcopy & E:\dbi\iec61000-6-1{ed2.0}b.pdf)



EN 61000-6-2:1999 Electromagnetic Compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments

Equivalent to: EN 61000-6-2:2001 (unmodified) & IEC 61000-6-2:1999 Edition 1
Replaces: EN 50082-2:1995
Replaced by: EN 61000-6-2:2001

For: European Union
Ratified/printed: APR 1999
May use starting: 25 JAN 2000
Must use starting: 1 APR 2002
Must use until: 9 MAR 2002
May use until: 1 JUL 2004

References:
* EN 55011:1998
* EN 55022:1998
* EN 61000-4-2:1995
* EN 61000-4-3:1996
* EN 61000-4-4:1995
* EN 61000-4-5:1995
* EN 61000-4-6:1996
* EN 61000-4-8:1993
* EN 61000-4-11:1994
* IEC 60050-161:1990

Referenced by:
* EN 55011:1998
* EN 61000-6-1:2001 (undated)

Comments:

(hardcopy & E:\dbi\EN61000-6-2.pdf)



EN 61000-6-2:2001 Electromagnetic Compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments

Equivalent to: EN 61000-6-2:1999 (modified) & IEC 61000-6-2:1999 Edition 1 (modified)
Replaces: EN 61000-6-2:1999
Replaced by: EN 61000-6-2:2005

For: European Union
Ratified/printed: 3 JUL 2001
May use starting: 9 MAR 2002
Must use starting: 1 JUL 2004
Must use until: 24 AUG 2006
May use until: 1 JUN 2008

References:
* EN 55011
* EN 55022
* EN 61000-4-2
* EN 61000-4-3
* EN 61000-4-4
* EN 61000-4-5
* EN 61000-4-6
* EN 61000-4-8
* EN 61000-4-11
* IEC 60050-161

Referenced by:
* EN 61000-6-1:2001 (undated)

Comments:

(hardcopy)



EN 61000-6-2:2005 Electromagnetic Compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments

Equivalent to: IEC 61000-6-2:2005 Edition 2
Replaces: EN 61000-6-2:2001
Replaced by:

For: European Union
Ratified/printed: 1 JUN 2005
May use starting: 24 AUG 2006
Must use starting: 1 JUN 2008
Must use until:
May use until:

References:
* CISPR 22
* IEC 60050-161
* IEC 61000-4-2
* IEC 61000-4-3
* IEC 61000-4-4
* IEC 61000-4-5
* IEC 61000-4-6
* IEC 61000-4-8
* IEC 61000-4-11

Referenced by:
* EN 61000-6-1:2001 (undated)

Comments:

(hardcopy & E:\dbi\61000-6-2_2005.pdf)



EN 61326:1997 Electrical equipment for measurement, control and laboratory use - EMC requirements

Equivalent to: IEC 61326:1997
Replaces:
Replaced by: EN 61326:1997+A1:1998

For: European Union
Ratified/printed: 11 MAR 1997
May use starting: 27 FEB 1999
Must use starting: 1 JUL 2001
Must use until: 27 FEB 1999
May use until: 1 JUL 2001

References:

Referenced by:

Comments:

(source)



EN 61326:1997+A1:1998 Electrical equipment for measurement, control and laboratory use - EMC requirements

Equivalent to: IEC 61326:1997+A1:1998
Replaces: EN 61326:1997
Replaced by: EN 61326:1997+A1:1998+A2:2001

For: European Union
Ratified/printed: 1 APR 1998
May use starting: 27 FEB 1999
Must use starting: 1 JUL 2001
Must use until: 9 MAR 2002
May use until: 1 APR 2004

References:

Referenced by:

Comments:

(source)



EN 61326:1997+A1:1998+A2:2001 Electrical equipment for measurement, control and laboratory use - EMC requirements

Equivalent to: IEC 61326:1997+A1:1998+A2:2000
Replaces: EN 61326:1997+A1:1998
Replaced by: EN 61326:1997+A1:1998+A2:2001+A3:2003

For: European Union
Ratified/printed: 1 MAR 2001
May use starting: 9 MAR 2002
Must use starting: 1 APR 2004
Must use until: 31 MAR 2005
May use until: 1 OCT 2006

References:

Referenced by:

Comments:

(source)



EN 61326:1997+A1:1998+A2:2001+A3:2003 Electrical equipment for measurement, control and laboratory use - EMC requirements

Equivalent to:
Replaces: EN 61326:1997+A1:1998+A2:2001
Replaced by: EN 61326-1:2006 & EN 61326-2-3:2006 & other EN 61326-2-x standards

For: European Union
Ratified/printed: 23 SEP 2003
May use starting: 31 MAR 2005
Must use starting: 1 OCT 2006
Must use until: 25 SEP 2007
May use until: 1 FEB 2009

References:

Referenced by:

Comments:

(source)



EN 61326-1:2006 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General Requirements

Equivalent to: IEC 61326-1:2005 Edition 1
Replaces: EN 61326:1997+A1:1998+A2:2001+A3:2003 in part
Replaced by:

For: European Union
Ratified/printed: 1 FEB 2006
May use starting: 25 SEP 2007
Must use starting: 1 FEB 2009
Must use until:
May use until:

References:
* CISPR 11:2003
* IEC 60050-161
* IEC 61000-3-2:2000
* IEC 61000-3-3:2002
* IEC 61000-3-11:2000
* IEC 61000-3-12:2004
* IEC 61000-4-2:2001
* IEC 61000-4-3:2002
* IEC 61000-4-4:2004
* IEC 61000-4-5:2001
* IEC 61000-4-6:2003
* IEC 61000-4-8:1993
* IEC 61000-4-11:2004
* IEC 61000-6-1:2005

Referenced by:

Comments:

(hardcopy & E:\dbi\iec61326-1{ed1.0}b.pdf)



EN 61326-2-3:2006 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning

Equivalent to: IEC 61326-2-3:2006 Edition 1
Replaces: EN 61326:1997+A1:1998+A2:2001+A3:2003 in part
Replaced by:

For: European Union
Ratified/printed: 1 AUG 2006
May use starting: 25 SEP 2007
Must use starting: 1 AUG 2009
Must use until:
May use until:

References:
* CISPR 11:2003
* IEC 60050-161
* IEC 60050-300
* IEC 61000-3-2:2000
* IEC 61000-3-3:2002
* IEC 61000-3-11:2000
* IEC 61000-3-12:2004
* IEC 61000-4-2:2001
* IEC 61000-4-3:2002
* IEC 61000-4-4:2004
* IEC 61000-4-5:2001
* IEC 61000-4-6:2003
* IEC 61000-4-8:1993
* IEC 61000-4-11:2004
* IEC 61000-6-1:2005

Referenced by:

Comments:

(hardcopy & E:\dbi\iec61326-2-3{ed1.0}b.pdf)



EN 61547:1995 Equipment for general lighting purposes - EMC immunity requirements

Equivalent to: IEC 61547:1995 Edition 1
Replaces:
Replaced by: EN 61547:1995+A1:2000

For: European Union
Ratified/printed: 20 SEP 1995
May use starting: 6 FEB 1997
Must use starting: 1 JUL 1996
Must use until: 9 MAR 2002
May use until: 1 NOV 2003

References:
* IEC 50(161):1990
* IEC 598-1:1992
* IEC 1000-4-2:1995
* IEC 1000-4-3:1995
* IEC 1000-4-4:1995
* IEC 1000-4-5:1995
* IEC/DIS 1000-4-6
* IEC 1000-4-8:1993
* IEC 1000-4-11:1994

Referenced by:

Comments:

(hardcopy & E:\dbi\iec61547{ed1.0}b.img.pdf)



EN 61547:1995+A1:2000 Equipment for general lighting purposes - EMC immunity requirements

Equivalent to: IEC 61547:1995+A1:2000
Replaces: EN 61547:1995
Replaced by: EN 61547:2009

For: European Union
Ratified/printed: 1 NOV 2000
May use starting: 9 MAR 2002
Must use starting: 1 NOV 2003
Must use until: 11 NOV 2010
May use until: 1 JUL 2012

References:
* IEC 50(161):1990
* IEC 598-1:1992
* IEC 1000-4-2:1995
* IEC 1000-4-3:1995
* IEC 1000-4-4:1995
* IEC 1000-4-5:1995
* IEC/DIS 1000-4-6
* IEC 1000-4-8:1993
* IEC 1000-4-11:1994

Referenced by:

Comments:

(hardcopy & E:\dbi\iec61547-amd1{ed1.0}b.pdf)



EN 61547:2009 Equipment for general lighting purposes - EMC immunity requirements

Equivalent to: IEC 61547:2009 Edition 2
Replaces: EN 61547:1995+A1:2000
Replaced by:

For: European Union
Ratified/printed: 1 JUL 2009
May use starting: 11 NOV 2010
Must use starting: 1 JUL 2012
Must use until:
May use until:

References:
* IEC 60050-161
* IEC 60050-845
* EN 60598-1:2008+A1:2009
* EN 60598-2-22:1998
* EN 61000-4-2:2009
* EN 61000-4-3:2006+A1:2008
* EN 61000-4-4:2004
* EN 61000-4-5:2006
* EN 61000-4-6:2009
* EN 61000-4-8:1993+A1:2001
* EN 61000-4-11:2004
* EN 61000-6-1:2007

Referenced by:

Comments:

(hardcopy & E:\dbi\I.S. EN 61547-2009.pdf)



IEC 61000-6-1:1997 Edition 1 Electromagnetic Compatibility (EMC) - Part 6: Generic standards - Section 1: Immunity for residential, commercial and light-industrial environments

Equivalent to: EN 61000-6-1:2001 (unmodified)
Replaces:
Replaced by: IEC 61000-6-1:2005 Edition 2

For:
Ratified/printed: JUL 1997
May use starting: JUL 1997
Must use starting: JUL 1997
Must use until: 9 MAR 2005
May use until: 9 MAR 2005

References:
* CISPR 22
* IEC 60050-161
* IEC 61000-4-2
* IEC 61000-4-3
* IEC 61000-4-4
* IEC 61000-4-5
* IEC 61000-4-6
* IEC 61000-4-8
* IEC 61000-4-11
* IEC 61000-6-2

Referenced by:

Comments:

(source)



IEC 61000-6-1:2005 Edition 2 Electromagnetic Compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments

Equivalent to: EN 61000-6-1:2007 & AS/NZS 61000.6.1:2006
Replaces: IEC 61000-6-1:1997 Edition 1
Replaced by:

For:
Ratified/printed: 9 MAR 2005
May use starting: 9 MAR 2005
Must use starting: 9 MAR 2005
Must use until:
May use until:

References:
* CISPR 22
* IEC 60050-161
* IEC 61000-4-2
* IEC 61000-4-3
* IEC 61000-4-4
* IEC 61000-4-5
* IEC 61000-4-6
* IEC 61000-4-8
* IEC 61000-4-11

Referenced by:
* EN 61326-1:2006
* EN 61326-2-3:2006
* IEC 61326-1:2005 Edition 1
* IEC 61326-2-3:2006 Edition 1

Comments:

(hardcopy & E:\dbi\iec61000-6-1{ed2.0}b.pdf)



IEC 61000-6-2:1999 Edition 1 Electromagnetic Compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments

Equivalent to: EN 61000-6-2:1999 & EN 61000-6-2:2001 (unmodified)
Replaces:
Replaced by: IEC 61000-6-2:2005 Edition 2

For:
Ratified/printed:
May use starting:
Must use starting:
Must use until: 27 JAN 2005
May use until: 27 JAN 2005

References:
* CISPR 11:1997
* CISPR 22:1997
* IEC 60050-161:1990
* IEC 61000-4-2:1995
* IEC 61000-4-3:1995
* IEC 61000-4-4:1995
* IEC 61000-4-5:1995
* IEC 61000-4-6:1996
* IEC 61000-4-8:1993
* IEC 61000-4-11:1994

Referenced by:
* IEC 61000-6-1:1997 (undated)

Comments:

(source)



IEC 61000-6-2:2005 Edition 2 Electromagnetic Compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments

Equivalent to: EN 61000-6-2:2005 & AS/NZS 61000.6.2:2006
Replaces: IEC 61000-6-2:1999 Edition 1
Replaced by:

For:
Ratified/printed: 27 JAN 2005
May use starting: 27 JAN 2005
Must use starting: 27 JAN 2005
Must use until:
May use until:

References:
* CISPR 22
* IEC 60050-161
* IEC 61000-4-2
* IEC 61000-4-3
* IEC 61000-4-4
* IEC 61000-4-5
* IEC 61000-4-6
* IEC 61000-4-8
* IEC 61000-4-11

Referenced by:
* IEC 61000-6-1:1997 Edition 1 (undated)

Comments:

(hardcopy & E:\dbi\61000-6-2_2005.pdf)



IEC 61326:1997 Electrical equipment for measurement, control and laboratory use - EMC requirements

Equivalent to: EN 61326:1997
Replaces:
Replaced by: IEC 61326:1997+A1:1998

For:
Ratified/printed:
May use starting:
Must use starting:
Must use until:
May use until:

References:

Referenced by:

Comments:

(source)



IEC 61326:1997+A1:1998 Electrical equipment for measurement, control and laboratory use - EMC requirements

Equivalent to: EN 61326:1997+A1:1998
Replaces: IEC 61326:1997
Replaced by: IEC 61326:1997+A1:1998+A2:2000

For:
Ratified/printed:
May use starting:
Must use starting:
Must use until:
May use until:

References:

Referenced by:

Comments:

(source)



IEC 61326:1997+A1:1998+A2:2000 Electrical equipment for measurement, control and laboratory use - EMC requirements

Equivalent to: EN 61326:1997+A1:1998+A2:2001
Replaces: IEC 61326:1997+A1:1998
Replaced by: IEC 61326:2002 Edition 1

For:
Ratified/printed:
May use starting:
Must use starting:
Must use until: FEB 2002
May use until: FEB 2002

References:

Referenced by:

Comments:

(source)



IEC 61326:2002 Edition 1 Electrical equipment for measurement, control and laboratory use - EMC requirements

Equivalent to:
Replaces: IEC 61326:1997+A1:1998+A2:2000
Replaced by: IEC 61326-1:2005 Edition 1 & IEC 61326-2-3:2006 Edition 1 & other IEC 61326-2-x standards

For:
Ratified/printed: FEB 2002
May use starting: FEB 2002
Must use starting: FEB 2002
Must use until: 15 DEC 2005
May use until: 15 DEC 2005

References:
* CISPR 11:1990
* CISPR 14-1:2000
* CISPR 16-1:1999
* CISPR 16-2:1996
* CISPR 22:1997
* IEC 60050-151:2001
* IEC 60050(161):1990
* IEC 60359
* IEC 61010
* IEC 61000-3-2:2000
* IEC 61000-3-3:1994
* IEC 61000-4-2:1995
* IEC 61000-4-3:1995
* IEC 61000-4-4:1995
* IEC 61000-4-5:1995
* IEC 61000-4-6:1996
* IEC 61000-4-8:1993
* IEC 61000-4-11:1994
* IEC 61557
* IEEE 488.1:1987
* IEEE 1284:1994
* TIA/EIA-232-F:1997

Referenced by:

Comments:

(hardcopy & E:\dbi\iec61326{ed1.0}b.pdf)



IEC 61326-1:2005 Edition 1 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General Requirements

Equivalent to: EN 61326-1:2006
Replaces: IEC 61326:2002 Edition 1 in part
Replaced by:

For:
Ratified/printed: 15 DEC 2005
May use starting: 15 DEC 2005
Must use starting: 15 DEC 2005
Must use until:
May use until:

References:
* CISPR 11:2003
* IEC 60050-161
* IEC 61000-3-2:2000
* IEC 61000-3-3:2002
* IEC 61000-3-11:2000
* IEC 61000-3-12:2004
* IEC 61000-4-2:2001
* IEC 61000-4-3:2002
* IEC 61000-4-4:2004
* IEC 61000-4-5:2001
* IEC 61000-4-6:2003
* IEC 61000-4-8:1993
* IEC 61000-4-11:2004
* IEC 61000-6-1:2005

Referenced by:

Comments:

(hardcopy & E:\dbi\iec61326-1{ed1.0}b.pdf)



IEC 61326-2-3:2006 Edition 1 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning

Equivalent to: EN 61326-2-3:2006
Replaces: IEC 61326:2002 Edition 1 in part
Replaced by:

For:
Ratified/printed: 10 JUL 2006
May use starting: 10 JUL 2006
Must use starting: 10 JUL 2006
Must use until:
May use until:

References:
* CISPR 11:2003
* IEC 60050-161
* IEC 60050-300
* IEC 61000-3-2:2000
* IEC 61000-3-3:2002
* IEC 61000-3-11:2000
* IEC 61000-3-12:2004
* IEC 61000-4-2:2001
* IEC 61000-4-3:2002
* IEC 61000-4-4:2004
* IEC 61000-4-5:2001
* IEC 61000-4-6:2003
* IEC 61000-4-8:1993
* IEC 61000-4-11:2004
* IEC 61000-6-1:2005

Referenced by:

Comments:

(hardcopy & E:\dbi\iec61326-2-3{ed1.0}b.pdf)



IEC 61547:1995 Edition 1 Equipment for general lighting purposes - EMC immunity requirements

Equivalent to:
EN 61547:1995
Replaces:
Replaced by: IEC 61547:1995+A1:2000

For:
Ratified/printed: SEP 1995
May use starting: SEP 1995
Must use starting: SEP 1995
Must use until: AUG 2000
May use until: AUG 2000

References:
* IEC 50(161):1990
* IEC 598-1:1992
* IEC 1000-4-2:1995
* IEC 1000-4-3:1995
* IEC 1000-4-4:1995
* IEC 1000-4-5:1995
* IEC/DIS 1000-4-6
* IEC 1000-4-8:1993
* IEC 1000-4-11:1994

Referenced by:

Comments:

(hardcopy & E:\dbi\iec61547{ed1.0}b.img.pdf)



IEC 61547:1995+A1:2000 Equipment for general lighting purposes - EMC immunity requirements

Equivalent to: EN 61547:1995+A1:2000

Replaces: IEC 61547:1995 Edition 1
Replaced by: IEC 61547:2009 Edition 2

For:
Ratified/printed: AUG 2000
May use starting: AUG 2000
Must use starting: AUG 2000
Must use until: 25 JUN 2009
May use until: 25 JUN 2009

References:
* IEC 50(161):1990
* IEC 598-1:1992
* IEC 1000-4-2:1995
* IEC 1000-4-3:1995
* IEC 1000-4-4:1995
* IEC 1000-4-5:1995
* IEC/DIS 1000-4-6
* IEC 1000-4-8:1993
* IEC 1000-4-11:1994

Referenced by:

Comments:

(hardcopy & E:\dbi\iec61547-amd1{ed1.0}b.pdf)



IEC 61547:2009 Edition 2 Equipment for general lighting purposes - EMC immunity requirements

Equivalent to: EN 61547:2009

Replaces: IEC 61547:1995+A1:2000
Replaced by:

For:
Ratified/printed: 25 JUN 2009
May use starting: 25 JUN 2009
Must use starting: 25 JUN 2009
Must use until:
May use until:

References:
* IEC 60050-161
* IEC 60050-845
* IEC 60598-1:2008
* IEC 60598-2-22
* IEC 61000-4-2:2008
* IEC 61000-4-3:2006
* IEC 61000-4-4:2004
* IEC 61000-4-5:2005
* IEC 61000-4-6:2008
* IEC 61000-4-8:1993
* IEC 61000-4-11:2004

Referenced by:

Comments:

(hardcopy & E:\dbi\I.S. EN 61547-2009.pdf)



DISCLAIMER
These web pages are freely offered to anyone who wishes to use them. No warranty for their use is expressed or implied. The most-current versions may be downloaded from the our web site at http://www.dbicorporation.com/.

These web pages can point you to regulations and standards applying to your product(s), but please refer to the regulations and standards themselves when deciding how to test your product(s). A regulation's or standard's title gives you strong clues as to what it covers, but its scope (usually section 1) tells you for sure. Carefully check the footnotes in tables, to see if your product falls into an exception that lets you avoid unnecessary tests (or sometimes requires additional special testing). Exceptions that can help you also sometimes hide in the Test Setup section (usually section 7). Also check the Test Report section (usually section 10) for any special documentation required.

COMMENTS
If you refer to one or more of these documents in written communications, please attribute them to http://www.dbicorporation.com/. Similarly, if you link to them from your own web page(s), we would appreciate an E-mail to jrbarnes@iglou.com giving the universal resource link (URL) so that we may provide a reciprocal link.

Please send critiques, corrections, and/or additions to jrbarnes@iglou.com , or by snailmail to:
John Barnes
216 Hillsboro Ave
Lexington, KY 40511-2105


dBi Corporation was a one-man test house (testing laboratory) based in Lexington, Kentucky, testing a wide variety of commercial electronic products for electromagnetic compatibility (EMC), electromagnetic interference (EMI), and electrostatic discharge (ESD) under its ISO 17025 accreditation. dBi was founded in Winchester, Kentucky in 1995 by Donald R. Bush, shortly after he retired from 30 years service with IBM Lexington's/ Lexmark's EMC Lab. John R. Barnes, who'd worked with Don at IBM Lexington and Lexmark, bought dBi in 2002 after Don's death, and moved the company to Lexington, Kentucky. John closed dBi at 11:59pm EDT on September 30, 2013, because ObamaCrap had increased operating expenses to the point that we could no longer afford to remain in business.

We'd like to thank all of the clients who chose dBi to test their products from 1995 to 2013. Below is a brief summary of our accomplishments during the 18 years we were in business.

From 1995 to 2001, under Don Bush's ownership and operation, dBi:

From 2002 to 2013, under John Barnes' ownership and operation, dBi:

Go to Main Web Site Index Go to Full Standards Index Go to ITE Standards Index Go to Residential/ Commercial Standards Index Go to Industrial Standards Index
Go to Lab Equipment Standards Index Go to Audio/ Video Equipment Standards Index Go to Lamps/ Luminaires Standards Index Go to Appliance Standards Index
Last revised December 2, 2011.